mirror of
https://github.com/Nanaloveyuki/BitLogger.git
synced 2026-07-24 00:42:18 +00:00
📝 refine library async lifecycle docs
This commit is contained in:
@@ -3,7 +3,7 @@ name: library-async-logger-is-enabled
|
||||
group: api
|
||||
category: facade
|
||||
update-time: 20260614
|
||||
description: Check whether a LibraryAsyncLogger facade would accept a record at a given level before using the repo's direct async call style.
|
||||
description: Check whether a LibraryAsyncLogger facade passes the wrapped async logger's min-level gate for a given severity.
|
||||
key-word:
|
||||
- async
|
||||
- library
|
||||
@@ -38,8 +38,9 @@ pub fn[S] LibraryAsyncLogger::is_enabled(
|
||||
Detailed rules explaining key parameters and behaviors
|
||||
|
||||
- This method delegates directly to the wrapped async logger's `is_enabled(...)` behavior.
|
||||
- It only checks logger-level severity gating; it does not evaluate later filter or overflow behavior.
|
||||
- The result reflects the current facade value, so derived facades with different thresholds can return different answers.
|
||||
- It only checks logger-level severity gating through `min_level`; it does not evaluate later filter, patch, closed-on-log, or overflow behavior.
|
||||
- The result reflects the current wrapped logger state, so derived facades with different thresholds can return different answers.
|
||||
- This check does not require unwrapping because it is part of the narrower library-facing surface.
|
||||
- Use it when message construction or field gathering is expensive enough to justify a pre-check.
|
||||
|
||||
### How to Use
|
||||
@@ -68,6 +69,8 @@ if logger.is_enabled(@bitlogger.Level::Warn) {
|
||||
|
||||
In this example, the check mirrors the same severity gate used by later async write calls.
|
||||
|
||||
And a `true` result still means only that the level gate passed, not that the record is guaranteed to reach the sink.
|
||||
|
||||
### Error Case
|
||||
|
||||
e.g.:
|
||||
@@ -75,8 +78,12 @@ e.g.:
|
||||
|
||||
- A `true` result does not guarantee final delivery if later queue or filter behavior rejects the record.
|
||||
|
||||
- If callers need to inspect queue or failure state instead of only checking the level gate, they must unwrap first with `to_async_logger()`.
|
||||
|
||||
### Notes
|
||||
|
||||
1. This is a cheap severity check, not a full end-to-end delivery guarantee.
|
||||
|
||||
2. Prefer using it only when precomputing the async log payload is meaningfully expensive.
|
||||
|
||||
3. Use `log(...)` or the severity shortcuts directly when no expensive precomputation needs to be avoided.
|
||||
|
||||
@@ -3,7 +3,7 @@ name: library-async-logger-run
|
||||
group: api
|
||||
category: facade
|
||||
update-time: 20260613
|
||||
description: Start the LibraryAsyncLogger worker loop so queued records are drained to the underlying sink.
|
||||
description: Start the LibraryAsyncLogger worker loop by delegating to the wrapped async logger's run behavior.
|
||||
key-word:
|
||||
- async
|
||||
- library
|
||||
@@ -37,6 +37,7 @@ Detailed rules explaining key parameters and behaviors
|
||||
- It starts the worker loop that makes accepted queued records reach the underlying sink.
|
||||
- Failure and lifecycle state are still tracked by the wrapped async logger.
|
||||
- The narrower library facade does not hide the need to explicitly activate queue draining.
|
||||
- If the worker fails, the wrapped async logger records that through its failure-state helpers, which still require `to_async_logger()` for inspection from library-facing code.
|
||||
|
||||
### How to Use
|
||||
|
||||
@@ -65,6 +66,8 @@ group.spawn_bg(() => logger.run())
|
||||
|
||||
In this example, the caller decides when the worker begins instead of hiding that lifecycle step.
|
||||
|
||||
And the started worker loop is still the same wrapped async logger runtime rather than a separate library-specific execution path.
|
||||
|
||||
### Error Case
|
||||
|
||||
e.g.:
|
||||
@@ -72,8 +75,12 @@ e.g.:
|
||||
|
||||
- If `run()` is never started, accepted records may remain queued and not reach the sink.
|
||||
|
||||
- If callers need to inspect `is_running()`, `has_failed()`, or `last_error()` directly, they must unwrap first with `to_async_logger()`.
|
||||
|
||||
### Notes
|
||||
|
||||
1. `LibraryAsyncLogger::new(...)` only constructs the facade; `run()` is what activates queue draining.
|
||||
|
||||
2. Pair this API with `shutdown()` for a complete worker lifecycle.
|
||||
|
||||
3. Use `to_async_logger()` first when operational code needs direct lifecycle or failure inspection in addition to starting the worker.
|
||||
|
||||
@@ -3,7 +3,7 @@ name: library-async-logger-shutdown
|
||||
group: api
|
||||
category: facade
|
||||
update-time: 20260614
|
||||
description: Gracefully stop a LibraryAsyncLogger by draining or clearing queued work, with worker-wait behavior depending on the active async runtime.
|
||||
description: Gracefully stop a LibraryAsyncLogger by delegating to the wrapped async logger's shutdown behavior, including runtime-dependent drain and worker-wait rules.
|
||||
key-word:
|
||||
- async
|
||||
- library
|
||||
@@ -42,6 +42,7 @@ Detailed rules explaining key parameters and behaviors
|
||||
- If the active async runtime uses shutdown clearing after idle and backlog still remains, the wrapped logger falls back to `close(clear=true)`.
|
||||
- `clear=true` immediately closes and abandons pending records.
|
||||
- In runtimes where shutdown waits for workers, the method then waits until the worker is no longer running before returning.
|
||||
- The narrower library facade does not change any of these runtime-dependent shutdown rules; it only keeps the broader inspection helpers out of the direct public surface.
|
||||
|
||||
### How to Use
|
||||
|
||||
@@ -65,6 +66,8 @@ logger.shutdown(clear=true)
|
||||
|
||||
In this example, pending work is abandoned intentionally so shutdown can complete sooner.
|
||||
|
||||
And the decision still applies to the same wrapped async logger state rather than a separate library-specific queue.
|
||||
|
||||
### Error Case
|
||||
|
||||
e.g.:
|
||||
@@ -74,6 +77,8 @@ e.g.:
|
||||
|
||||
- If callers skip `shutdown()` and only inspect flags manually, it is easier to leave the worker lifecycle in an unclear state.
|
||||
|
||||
- If callers need to inspect `pending_count()`, `dropped_count()`, `is_running()`, or failure state during shutdown analysis, they must unwrap first with `to_async_logger()`.
|
||||
|
||||
### Notes
|
||||
|
||||
1. Prefer this API over low-level closure control in normal library shutdown paths.
|
||||
@@ -81,3 +86,5 @@ e.g.:
|
||||
2. Exact post-close waiting behavior depends on the active async runtime mode.
|
||||
|
||||
3. Choose `clear=true` only when loss of queued records is acceptable.
|
||||
|
||||
4. Use `to_async_logger()` first when shutdown orchestration also needs direct lifecycle or backlog inspection.
|
||||
|
||||
Reference in New Issue
Block a user